Tag | (0028,0300) |
---|---|
Type | Optional (3) |
Keyword | QualityControlImage |
Value Multiplicity | 1 |
Value Representation | Code String (CS) |
Example Values |
|
Indicates whether or not quality control material (such as calibration or control material, or a phantom) is present in this image.
Enumerated Values:
the image contains only quality control material
the image does not contain quality control material
the image contains both subject (patient) and quality control information
If this Attribute is absent, then the image may or may not be a quality control or phantom image. The phantom device or quality control material in the image can be described using the Device Module. See Section C.7.6.12.
Examples of the presence of both subject and quality control information include:
presence of objects of known density in radiographic images for calibration
presence of control material for immunohistochemistry within slide images
Table C.7-18 specifies the Attributes of the Device Module, which identifies and describes devices or calibration objects (e.g., catheters, markers, baskets) or other quality control materials that are associated with a Study and/or image.
Table C.7-18. Device Module Attributes
Attribute Name |
Tag |
Type |
Attribute Description |
---|---|---|---|
Device Sequence |
(0050,0010) |
1 |
A Sequence of Items describing devices used that may be visible in the image. One or more Items shall be included in this Sequence. |
>Manufacturer |
(0008,0070) |
3 |
Manufacturer of the device. |
>Manufacturer's Model Name |
(0008,1090) |
3 |
Manufacturer's model name of the device. |
>Device Serial Number |
(0018,1000) |
3 |
Manufacturer's serial number of the device. |
>Date of Manufacture |
(0018,1204) |
3 |
The date the device was originally manufactured or re-manufactured (as opposed to refurbished). |
>Device ID |
(0018,1003) |
3 |
User-supplied identifier for the device. |
>Device Length |
(0050,0014) |
3 |
Length in mm of device. See Section C.7.6.12.1.1. |
>Device Diameter |
(0050,0016) |
3 |
Unit diameter of device. See Section C.7.6.12.1.1. |
>Device Diameter Units |
(0050,0017) |
2C |
Required if Device Diameter (0050,0016) is present. Defined Terms:
|
>Device Volume |
(0050,0018) |
3 |
Volume of device in ml. See Section C.7.6.12.1.1. |
>Inter-Marker Distance |
(0050,0019) |
3 |
Distance in mm between markers on calibrated device. See Section C.7.6.12.1.1. |
>Device Description |
(0050,0020) |
3 |
Further description in free form text describing the device. |
Depending on the type of device specified by Code Value (0008,0100) in an Item of Device Sequence (0050,0010), various device size Attributes (e.g., Device Length (0050,0014), Device Diameter (0050,0016), Device Volume (0050,0018), Inter Marker Distance (0050,0019)) may be required to fully characterize the device.
Table C.7-18 specifies the Attributes of the Device Module, which identifies and describes devices or calibration objects (e.g., catheters, markers, baskets) or other quality control materials that are associated with a Study and/or image.
Table C.7-18. Device Module Attributes
Attribute Name |
Tag |
Type |
Attribute Description |
---|---|---|---|
Device Sequence |
(0050,0010) |
1 |
A Sequence of Items describing devices used that may be visible in the image. One or more Items shall be included in this Sequence. |
>Manufacturer |
(0008,0070) |
3 |
Manufacturer of the device. |
>Manufacturer's Model Name |
(0008,1090) |
3 |
Manufacturer's model name of the device. |
>Device Serial Number |
(0018,1000) |
3 |
Manufacturer's serial number of the device. |
>Date of Manufacture |
(0018,1204) |
3 |
The date the device was originally manufactured or re-manufactured (as opposed to refurbished). |
>Device ID |
(0018,1003) |
3 |
User-supplied identifier for the device. |
>Device Length |
(0050,0014) |
3 |
Length in mm of device. See Section C.7.6.12.1.1. |
>Device Diameter |
(0050,0016) |
3 |
Unit diameter of device. See Section C.7.6.12.1.1. |
>Device Diameter Units |
(0050,0017) |
2C |
Required if Device Diameter (0050,0016) is present. Defined Terms:
|
>Device Volume |
(0050,0018) |
3 |
Volume of device in ml. See Section C.7.6.12.1.1. |
>Inter-Marker Distance |
(0050,0019) |
3 |
Distance in mm between markers on calibrated device. See Section C.7.6.12.1.1. |
>Device Description |
(0050,0020) |
3 |
Further description in free form text describing the device. |
Depending on the type of device specified by Code Value (0008,0100) in an Item of Device Sequence (0050,0010), various device size Attributes (e.g., Device Length (0050,0014), Device Diameter (0050,0016), Device Volume (0050,0018), Inter Marker Distance (0050,0019)) may be required to fully characterize the device.