Computed Radiography ImageCIOD
CT ImageCIOD
MR ImageCIOD
Nuclear Medicine ImageCIOD
Ultrasound ImageCIOD
Ultrasound Multi-frame ImageCIOD
Secondary Capture ImageCIOD
Multi-frame Single Bit Secondary Capture ImageCIOD
Multi-frame Grayscale Byte Secondary Capture ImageCIOD
Multi-frame Grayscale Word Secondary Capture ImageCIOD
Multi-frame True Color Secondary Capture ImageCIOD
X-Ray Angiographic ImageCIOD
X-Ray Radiofluoroscopic ImageCIOD
RT ImageCIOD
RT DoseCIOD
RT Structure SetCIOD
RT PlanCIOD
Positron Emission Tomography ImageCIOD
Digital X-Ray ImageCIOD
Digital Mammography X-Ray ImageCIOD
Digital Intra-Oral X-Ray ImageCIOD
RT Beams Treatment RecordCIOD
RT Brachy Treatment RecordCIOD
RT Treatment Summary RecordCIOD
VL Endoscopic ImageCIOD
VL Microscopic ImageCIOD
VL Slide-Coordinates Microscopic ImageCIOD
VL Photographic ImageCIOD
Video Endoscopic ImageCIOD
Video Microscopic ImageCIOD
Video Photographic ImageCIOD
VL Whole Slide Microscopy ImageCIOD
Real-Time Video Endoscopic ImageCIOD
Real-Time Video Photographic ImageCIOD
Dermoscopic Photography ImageCIOD
Grayscale Softcopy Presentation StateCIOD
Color Softcopy Presentation StateCIOD
Pseudo-Color Softcopy Presentation StateCIOD
Blending Softcopy Presentation StateCIOD
Basic Structured DisplayCIOD
XA/XRF Grayscale Softcopy Presentation StateCIOD
Advanced Blending Presentation StateCIOD
Variable Modality LUT Softcopy Presentation StateCIOD
Basic Voice Audio WaveformCIOD
12-Lead ECGCIOD
General ECGCIOD
Ambulatory ECGCIOD
Hemodynamic WaveformCIOD
Basic Cardiac Electrophysiology WaveformCIOD
Arterial Pulse WaveformCIOD
Respiratory WaveformCIOD
General Audio WaveformCIOD
Real-Time Audio WaveformCIOD
Routine Scalp ElectroencephalogramCIOD
ElectromyogramCIOD
ElectrooculogramCIOD
Sleep ElectroencephalogramCIOD
Multi-channel Respiratory WaveformCIOD
Body Position WaveformCIOD
General 32-bit ECGCIOD
Basic Text SRCIOD
Enhanced SRCIOD
Comprehensive SRCIOD
Key Object Selection DocumentCIOD
Mammography CAD SRCIOD
Chest CAD SRCIOD
Procedure LogCIOD
X-Ray Radiation Dose SRCIOD
Spectacle Prescription ReportCIOD
Colon CAD SRCIOD
Macular Grid Thickness and Volume ReportCIOD
Implantation Plan SR DocumentCIOD
Comprehensive 3D SRCIOD
Radiopharmaceutical Radiation Dose SRCIOD
Extensible SRCIOD
Acquisition Context SRCIOD
Simplified Adult Echo SRCIOD
Patient Radiation Dose SRCIOD
Planned Imaging Agent Administration SRCIOD
Performed Imaging Agent Administration SRCIOD
Rendition Selection DocumentCIOD
Enhanced X-Ray Radiation Dose SRCIOD
Enhanced MR ImageCIOD
MR SpectroscopyCIOD
Enhanced MR Color ImageCIOD
Raw DataCIOD
Enhanced CT ImageCIOD
Spatial RegistrationCIOD
Deformable Spatial RegistrationCIOD
Spatial FiducialsCIOD
Ophthalmic Photography 8 Bit ImageCIOD
Ophthalmic Photography 16 Bit ImageCIOD
Stereometric RelationshipCIOD
Hanging ProtocolCIOD
Encapsulated PDFCIOD
Encapsulated CDACIOD
Real World Value MappingCIOD
Enhanced XA ImageCIOD
Enhanced XRF ImageCIOD
RT Ion PlanCIOD
RT Ion Beams Treatment RecordCIOD
SegmentationCIOD
Ophthalmic Tomography ImageCIOD
X-Ray 3D Angiographic ImageCIOD
X-Ray 3D Craniofacial ImageCIOD
Breast Tomosynthesis ImageCIOD
Enhanced PET ImageCIOD
Surface SegmentationCIOD
Color PaletteCIOD
Enhanced US VolumeCIOD
Lensometry MeasurementsCIOD
Autorefraction MeasurementsCIOD
PatientMModule - Patient
Clinical Trial SubjectUModule - Patient
General StudyMModule - Study
(0008,0020) Study Date2Date
(0008,0030) Study Time2Time
(0008,0050) Accession Number2Short String
(0008,0051) Issuer of Accession Number Sequence3Sequence
(0008,0090) Referring Physician's Name2Person Name
(0008,0096) Referring Physician Identification Sequence3Sequence
(0008,009C) Consulting Physician's Name3Person Name
(0008,009D) Consulting Physician Identification Sequence3Sequence
(0008,1030) Study Description3Long String
(0008,1032) Procedure Code Sequence3Sequence
(0008,1048) Physician(s) of Record3Person Name
(0008,1049) Physician(s) of Record Identification Sequence3Sequence
(0008,1060) Name of Physician(s) Reading Study3Person Name
(0008,1062) Physician(s) Reading Study Identification Sequence3Sequence
(0008,0080) Institution Name1CLong String
(0008,0081) Institution Address3Short Text
(0008,0082) Institution Code Sequence1CSequence
(0008,1040) Institutional Department Name3Long String
(0008,1041) Institutional Department Type Code Sequence3Sequence
(0040,1101) Person Identification Code Sequence1Sequence
(0008,0100) Code Value1CShort String
(0008,0102) Coding Scheme Designator1CShort String
(0008,0103) Coding Scheme Version1CShort String
(0008,0104) Code Meaning1Long String
(0008,0105) Mapping Resource1CCode String
(0008,0106) Context Group Version1CDate Time
(0008,0107) Context Group Local Version1CDate Time
(0008,010B) Context Group Extension Flag3Code String
(0008,010D) Context Group Extension Creator UID1CUnique Identifier
(0008,010F) Context Identifier3Code String
(0008,0117) Context UID3Unique Identifier
(0008,0118) Mapping Resource UID3Unique Identifier
(0008,0119) Long Code Value1CUnlimited Characters
(0008,0120) URN Code Value1CURL
(0008,0121) Equivalent Code Sequence3Sequence
(0008,0100) Code Value1CShort String
(0008,0102) Coding Scheme Designator1CShort String
(0008,0103) Coding Scheme Version1CShort String
(0008,0104) Code Meaning1Long String
(0008,0105) Mapping Resource1CCode String
(0008,0106) Context Group Version1CDate Time
(0008,0107) Context Group Local Version1CDate Time
(0008,010B) Context Group Extension Flag3Code String
(0008,010D) Context Group Extension Creator UID1CUnique Identifier
(0008,010F) Context Identifier3Code String
(0008,0117) Context UID3Unique Identifier
(0008,0118) Mapping Resource UID3Unique Identifier
(0008,0119) Long Code Value1CUnlimited Characters
(0008,0120) URN Code Value1CURL
(0008,0122) Mapping Resource Name3Long String
(0008,0122) Mapping Resource Name3Long String
(0040,1102) Person's Address3Short Text
(0040,1103) Person's Telephone Numbers3Long String
(0040,1104) Person's Telecom Information3Long Text
(0008,1110) Referenced Study Sequence3Sequence
(0020,000D) Study Instance UID1Unique Identifier
(0020,0010) Study ID2Short String
(0032,1033) Requesting Service3Long String
(0032,1034) Requesting Service Code Sequence3Sequence
(0040,1012) Reason For Performed Procedure Code Sequence3Sequence
Patient StudyUModule - Study
Clinical Trial StudyUModule - Study
General SeriesMModule - Series
Autorefraction Measurements SeriesMModule - Series
Clinical Trial SeriesUModule - Series
General EquipmentMModule - Equipment
Enhanced General EquipmentMModule - Equipment
General Ophthalmic Refractive MeasurementsMModule - Measurements
Autorefraction MeasurementsMModule - Measurements
SOP CommonMModule - Measurements
Keratometry MeasurementsCIOD
Subjective Refraction MeasurementsCIOD
Visual Acuity MeasurementsCIOD
Ophthalmic Axial MeasurementsCIOD
Intraocular Lens CalculationsCIOD
Generic Implant TemplateCIOD
Implant Assembly TemplateCIOD
Implant Template GroupCIOD
RT Beams Delivery InstructionCIOD
Ophthalmic Visual Field Static Perimetry MeasurementsCIOD
Intravascular Optical Coherence Tomography ImageCIOD
Ophthalmic Thickness MapCIOD
Surface Scan MeshCIOD
Surface Scan Point CloudCIOD
Legacy Converted Enhanced CT ImageCIOD
Legacy Converted Enhanced MR ImageCIOD
Legacy Converted Enhanced PET ImageCIOD
Corneal Topography MapCIOD
Breast Projection X-Ray ImageCIOD
Parametric MapCIOD
Wide Field Ophthalmic Photography Stereographic Projection ImageCIOD
Wide Field Ophthalmic Photography 3D Coordinates ImageCIOD
Tractography ResultsCIOD
RT Brachy Application Setup Delivery InstructionCIOD
Planar MPR Volumetric Presentation StateCIOD
Volume Rendering Volumetric Presentation StateCIOD
Content Assessment ResultsCIOD
CT Performed Procedure ProtocolCIOD
CT Defined Procedure ProtocolCIOD
Protocol ApprovalCIOD
XA Performed Procedure ProtocolCIOD
XA Defined Procedure ProtocolCIOD
Ophthalmic Optical Coherence Tomography En Face ImageCIOD
Ophthalmic Optical Coherence Tomography B-scan Volume AnalysisCIOD
Encapsulated STLCIOD
Encapsulated OBJCIOD
Encapsulated MTLCIOD
RT Physician IntentCIOD
RT Segment AnnotationCIOD
RT Radiation SetCIOD
C-Arm Photon-Electron RadiationCIOD
Tomotherapeutic RadiationCIOD
Robotic-Arm RadiationCIOD
RT Radiation Record SetCIOD
RT Radiation Salvage RecordCIOD
C-Arm Photon-Electron Radiation RecordCIOD
Tomotherapeutic Radiation RecordCIOD
Robotic-Arm Radiation RecordCIOD
RT Radiation Set Delivery InstructionCIOD
RT Treatment PreparationCIOD
Enhanced RT ImageCIOD
Enhanced Continuous RT ImageCIOD
RT Patient Position Acquisition InstructionCIOD
Microscopy Bulk Simple AnnotationsCIOD
InventoryCIOD
Photoacoustic ImageCIOD
Confocal Microscopy ImageCIOD
Confocal Microscopy Tiled Pyramidal ImageCIOD
Basic DirectoryCIOD

Built with by Innolitics, a team of medical imaging software developers.

Data synced with official DICOM standard on 18 April 2024. The DICOM Standard is under continuous maintenance, and the current official version is available at http://www.dicomstandard.org/current/. DICOM Parts 3, 4, and 6, © NEMA. Please note that the most recent PDF version of the standard is the official reference, and should checked when making technical decisions.

URN Code Value Attribute

Tag(0008,0120)
TypeConditionally Required (1C)
KeywordURNCodeValue
Value Multiplicity1
Value RepresentationURL (UR)

The identifier of the Coded Entry.

See Section 8.1.

Shall be present if Code Value (0008,0100) is not present and the Code Value is a URN or URL.

Section 8.1

8.1 Code Value

Code Value (0008,0100) is an identifier that is unambiguous within the Coding Scheme denoted by Coding Scheme Designator (0008,0102) and Coding Scheme Version (0008,0103).

The Long Code Value (0008,0119) or URN Code Value (0008,0120) is only used for codes that exceed the 16 character size limit of Code Value (0008,0100). If the code value length exceeds 16, the Code Value (0008,0100) shall not be present. If the code value length is 16 characters or less, the Code Value (0008,0100) shall contain the code and neither Long Code Value (0008,0119) nor URN Code Value (0008,0120) shall be present. The URN Code Value (0008,0120) shall be used for codes that are represented using URN or URL notation. The Long Code Value (0008,0119) shall be used for codes that are represented using other notations and that exceed 16 characters in length.

Note

The Code Value is typically not a natural language string, e.g., "76752008".