Computed Radiography ImageCIOD
CT ImageCIOD
MR ImageCIOD
Nuclear Medicine ImageCIOD
Ultrasound ImageCIOD
Ultrasound Multi-frame ImageCIOD
Secondary Capture ImageCIOD
Multi-frame Single Bit Secondary Capture ImageCIOD
Multi-frame Grayscale Byte Secondary Capture ImageCIOD
Multi-frame Grayscale Word Secondary Capture ImageCIOD
Multi-frame True Color Secondary Capture ImageCIOD
X-Ray Angiographic ImageCIOD
X-Ray Radiofluoroscopic ImageCIOD
RT ImageCIOD
RT DoseCIOD
RT Structure SetCIOD
RT PlanCIOD
Positron Emission Tomography ImageCIOD
Digital X-Ray ImageCIOD
Digital Mammography X-Ray ImageCIOD
Digital Intra-Oral X-Ray ImageCIOD
RT Beams Treatment RecordCIOD
PatientMModule - Patient
Clinical Trial SubjectUModule - Patient
General StudyMModule - Study
Patient StudyUModule - Study
Clinical Trial StudyUModule - Study
RT SeriesMModule - Series
Clinical Trial SeriesUModule - Series
General EquipmentMModule - Equipment
RT General Treatment RecordMModule - Treatment Record
RT Patient SetupUModule - Treatment Record
RT Treatment Machine RecordMModule - Treatment Record
Measured Dose Reference RecordUModule - Treatment Record
Calculated Dose Reference RecordUModule - Treatment Record
RT Beams Session RecordMModule - Treatment Record
(3008,0020) Treatment Session Beam Sequence1Sequence
(0008,1156) Definition Source Sequence3Sequence
(3002,0050) Primary Fluence Mode Sequence3Sequence
(3008,0022) Current Fraction Number2Integer String
(3008,002A) Treatment Termination Status1Code String
(3008,002C) Treatment Verification Status2Code String
(3008,0032) Specified Primary Meterset3Decimal String
(3008,0033) Specified Secondary Meterset3Decimal String
(3008,0036) Delivered Primary Meterset3Decimal String
(3008,0037) Delivered Secondary Meterset3Decimal String
(3008,003A) Specified Treatment Time3Decimal String
(3008,003B) Delivered Treatment Time3Decimal String
(3008,0040) Control Point Delivery Sequence1Sequence
(3008,0080) Referenced Measured Dose Reference Sequence3Sequence
(3008,0090) Referenced Calculated Dose Reference Sequence3Sequence
(3008,00A0) Beam Limiting Device Leaf Pairs Sequence1CSequence
(3008,00A1) Enhanced RT Beam Limiting Device Sequence1CSequence
(3008,00A3) Enhanced RT Beam Limiting Device Definition Flag3Code String
(3008,00B0) Recorded Wedge Sequence1CSequence
(3008,00C0) Recorded Compensator Sequence3Sequence
(3008,00D0) Recorded Block Sequence3Sequence
(300A,00B4) Source-Axis Distance3Decimal String
(300A,00C2) Beam Name3Long String
(300A,00C3) Beam Description3Short Text
(300A,00C4) Beam Type1Code String
(300A,00C6) Radiation Type1Code String
(300A,00C7) High-Dose Technique Type1CCode String
(300A,00CE) Treatment Delivery Type2Code String
(300A,00D0) Number of Wedges1Integer String
(300A,00E0) Number of Compensators2Integer String
(300A,00ED) Number of Boli2Integer String
(300A,00F0) Number of Blocks2Integer String
(300A,0107) Applicator Sequence3Sequence
(300A,0110) Number of Control Points1Integer String
(300A,0420) General Accessory Sequence3Sequence
(300A,065A) Radiation Device Configuration and Commissioning Key Sequence1CSequence
(300A,0715) RT Treatment Termination Reason Code Sequence3Sequence
(300A,0716) Machine-Specific Treatment Termination Code Sequence3Sequence
(300A,0730) Treatment Termination Description3Short Text
(300A,0740) Interlock Sequence3Sequence
(300C,0006) Referenced Beam Number3Integer String
(300C,0040) Referenced Verification Image Sequence3Sequence
(300C,006A) Referenced Patient Setup Number3Integer String
(300C,00B0) Referenced Bolus Sequence3Sequence
(300C,0120) Dose Calibration Conditions Sequence1CSequence
(300C,0123) Dose Calibration Conditions Verified Flag3Code String
(300C,0125) Gating Beam Hold Transition Sequence3Sequence
(3010,0038) Entity Long Label3Long String
(300A,0078) Number of Fractions Planned2Integer String
(300A,00B3) Primary Dosimeter Unit1Code String
(300C,0022) Referenced Fraction Group Number3Integer String
RT Treatment Summary RecordUModule - Treatment Record
General ReferenceUModule - Treatment Record
SOP CommonMModule - Treatment Record
Common Instance ReferenceUModule - Treatment Record
RT Brachy Treatment RecordCIOD
RT Treatment Summary RecordCIOD
VL Endoscopic ImageCIOD
VL Microscopic ImageCIOD
VL Slide-Coordinates Microscopic ImageCIOD
VL Photographic ImageCIOD
Video Endoscopic ImageCIOD
Video Microscopic ImageCIOD
Video Photographic ImageCIOD
VL Whole Slide Microscopy ImageCIOD
Real-Time Video Endoscopic ImageCIOD
Real-Time Video Photographic ImageCIOD
Dermoscopic Photography ImageCIOD
Grayscale Softcopy Presentation StateCIOD
Color Softcopy Presentation StateCIOD
Pseudo-Color Softcopy Presentation StateCIOD
Blending Softcopy Presentation StateCIOD
Basic Structured DisplayCIOD
XA/XRF Grayscale Softcopy Presentation StateCIOD
Advanced Blending Presentation StateCIOD
Variable Modality LUT Softcopy Presentation StateCIOD
Basic Voice Audio WaveformCIOD
12-Lead ECGCIOD
General ECGCIOD
Ambulatory ECGCIOD
Hemodynamic WaveformCIOD
Basic Cardiac Electrophysiology WaveformCIOD
Arterial Pulse WaveformCIOD
Respiratory WaveformCIOD
General Audio WaveformCIOD
Real-Time Audio WaveformCIOD
Routine Scalp ElectroencephalogramCIOD
ElectromyogramCIOD
ElectrooculogramCIOD
Sleep ElectroencephalogramCIOD
Multi-channel Respiratory WaveformCIOD
Body Position WaveformCIOD
General 32-bit ECGCIOD
Basic Text SRCIOD
Enhanced SRCIOD
Comprehensive SRCIOD
Key Object Selection DocumentCIOD
Mammography CAD SRCIOD
Chest CAD SRCIOD
Procedure LogCIOD
X-Ray Radiation Dose SRCIOD
Spectacle Prescription ReportCIOD
Colon CAD SRCIOD
Macular Grid Thickness and Volume ReportCIOD
Implantation Plan SR DocumentCIOD
Comprehensive 3D SRCIOD
Radiopharmaceutical Radiation Dose SRCIOD
Extensible SRCIOD
Acquisition Context SRCIOD
Simplified Adult Echo SRCIOD
Patient Radiation Dose SRCIOD
Planned Imaging Agent Administration SRCIOD
Performed Imaging Agent Administration SRCIOD
Rendition Selection DocumentCIOD
Enhanced X-Ray Radiation Dose SRCIOD
Enhanced MR ImageCIOD
MR SpectroscopyCIOD
Enhanced MR Color ImageCIOD
Raw DataCIOD
Enhanced CT ImageCIOD
Spatial RegistrationCIOD
Deformable Spatial RegistrationCIOD
Spatial FiducialsCIOD
Ophthalmic Photography 8 Bit ImageCIOD
Ophthalmic Photography 16 Bit ImageCIOD
Stereometric RelationshipCIOD
Hanging ProtocolCIOD
Encapsulated PDFCIOD
Encapsulated CDACIOD
Real World Value MappingCIOD
Enhanced XA ImageCIOD
Enhanced XRF ImageCIOD
RT Ion PlanCIOD
RT Ion Beams Treatment RecordCIOD
SegmentationCIOD
Ophthalmic Tomography ImageCIOD
X-Ray 3D Angiographic ImageCIOD
X-Ray 3D Craniofacial ImageCIOD
Breast Tomosynthesis ImageCIOD
Enhanced PET ImageCIOD
Surface SegmentationCIOD
Color PaletteCIOD
Enhanced US VolumeCIOD
Lensometry MeasurementsCIOD
Autorefraction MeasurementsCIOD
Keratometry MeasurementsCIOD
Subjective Refraction MeasurementsCIOD
Visual Acuity MeasurementsCIOD
Ophthalmic Axial MeasurementsCIOD
Intraocular Lens CalculationsCIOD
Generic Implant TemplateCIOD
Implant Assembly TemplateCIOD
Implant Template GroupCIOD
RT Beams Delivery InstructionCIOD
Ophthalmic Visual Field Static Perimetry MeasurementsCIOD
Intravascular Optical Coherence Tomography ImageCIOD
Ophthalmic Thickness MapCIOD
Surface Scan MeshCIOD
Surface Scan Point CloudCIOD
Legacy Converted Enhanced CT ImageCIOD
Legacy Converted Enhanced MR ImageCIOD
Legacy Converted Enhanced PET ImageCIOD
Corneal Topography MapCIOD
Breast Projection X-Ray ImageCIOD
Parametric MapCIOD
Wide Field Ophthalmic Photography Stereographic Projection ImageCIOD
Wide Field Ophthalmic Photography 3D Coordinates ImageCIOD
Tractography ResultsCIOD
RT Brachy Application Setup Delivery InstructionCIOD
Planar MPR Volumetric Presentation StateCIOD
Volume Rendering Volumetric Presentation StateCIOD
Content Assessment ResultsCIOD
CT Performed Procedure ProtocolCIOD
CT Defined Procedure ProtocolCIOD
Protocol ApprovalCIOD
XA Performed Procedure ProtocolCIOD
XA Defined Procedure ProtocolCIOD
Ophthalmic Optical Coherence Tomography En Face ImageCIOD
Ophthalmic Optical Coherence Tomography B-scan Volume AnalysisCIOD
Encapsulated STLCIOD
Encapsulated OBJCIOD
Encapsulated MTLCIOD
RT Physician IntentCIOD
RT Segment AnnotationCIOD
RT Radiation SetCIOD
C-Arm Photon-Electron RadiationCIOD
Tomotherapeutic RadiationCIOD
Robotic-Arm RadiationCIOD
RT Radiation Record SetCIOD
RT Radiation Salvage RecordCIOD
C-Arm Photon-Electron Radiation RecordCIOD
Tomotherapeutic Radiation RecordCIOD
Robotic-Arm Radiation RecordCIOD
RT Radiation Set Delivery InstructionCIOD
RT Treatment PreparationCIOD
Enhanced RT ImageCIOD
Enhanced Continuous RT ImageCIOD
RT Patient Position Acquisition InstructionCIOD
Microscopy Bulk Simple AnnotationsCIOD
InventoryCIOD
Photoacoustic ImageCIOD
Confocal Microscopy ImageCIOD
Confocal Microscopy Tiled Pyramidal ImageCIOD
Basic DirectoryCIOD

Built with by Innolitics, a team of medical imaging software developers.

Data synced with official DICOM standard on 18 April 2024. The DICOM Standard is under continuous maintenance, and the current official version is available at http://www.dicomstandard.org/current/. DICOM Parts 3, 4, and 6, © NEMA. Please note that the most recent PDF version of the standard is the official reference, and should checked when making technical decisions.

Beam Description Attribute

Tag(300A,00C3)
TypeOptional (3)
KeywordBeamDescription
Value Multiplicity1
Value RepresentationShort Text (ST)

User-defined description for delivered Beam.