Computed Radiography ImageCIOD
CT ImageCIOD
MR ImageCIOD
Nuclear Medicine ImageCIOD
Ultrasound ImageCIOD
Ultrasound Multi-frame ImageCIOD
Secondary Capture ImageCIOD
Multi-frame Single Bit Secondary Capture ImageCIOD
Multi-frame Grayscale Byte Secondary Capture ImageCIOD
Multi-frame Grayscale Word Secondary Capture ImageCIOD
Multi-frame True Color Secondary Capture ImageCIOD
X-Ray Angiographic ImageCIOD
X-Ray Radiofluoroscopic ImageCIOD
RT ImageCIOD
RT DoseCIOD
RT Structure SetCIOD
RT PlanCIOD
Positron Emission Tomography ImageCIOD
Digital X-Ray ImageCIOD
Digital Mammography X-Ray ImageCIOD
Digital Intra-Oral X-Ray ImageCIOD
RT Beams Treatment RecordCIOD
RT Brachy Treatment RecordCIOD
RT Treatment Summary RecordCIOD
VL Endoscopic ImageCIOD
VL Microscopic ImageCIOD
VL Slide-Coordinates Microscopic ImageCIOD
VL Photographic ImageCIOD
Video Endoscopic ImageCIOD
Video Microscopic ImageCIOD
Video Photographic ImageCIOD
VL Whole Slide Microscopy ImageCIOD
Real-Time Video Endoscopic ImageCIOD
Real-Time Video Photographic ImageCIOD
Dermoscopic Photography ImageCIOD
Grayscale Softcopy Presentation StateCIOD
Color Softcopy Presentation StateCIOD
Pseudo-Color Softcopy Presentation StateCIOD
Blending Softcopy Presentation StateCIOD
Basic Structured DisplayCIOD
XA/XRF Grayscale Softcopy Presentation StateCIOD
Advanced Blending Presentation StateCIOD
Variable Modality LUT Softcopy Presentation StateCIOD
Basic Voice Audio WaveformCIOD
12-Lead ECGCIOD
General ECGCIOD
Ambulatory ECGCIOD
Hemodynamic WaveformCIOD
Basic Cardiac Electrophysiology WaveformCIOD
Arterial Pulse WaveformCIOD
Respiratory WaveformCIOD
General Audio WaveformCIOD
Real-Time Audio WaveformCIOD
Routine Scalp ElectroencephalogramCIOD
ElectromyogramCIOD
ElectrooculogramCIOD
Sleep ElectroencephalogramCIOD
Multi-channel Respiratory WaveformCIOD
Body Position WaveformCIOD
General 32-bit ECGCIOD
Basic Text SRCIOD
Enhanced SRCIOD
Comprehensive SRCIOD
Key Object Selection DocumentCIOD
Mammography CAD SRCIOD
Chest CAD SRCIOD
Procedure LogCIOD
X-Ray Radiation Dose SRCIOD
Spectacle Prescription ReportCIOD
Colon CAD SRCIOD
Macular Grid Thickness and Volume ReportCIOD
Implantation Plan SR DocumentCIOD
Comprehensive 3D SRCIOD
Radiopharmaceutical Radiation Dose SRCIOD
Extensible SRCIOD
Acquisition Context SRCIOD
Simplified Adult Echo SRCIOD
Patient Radiation Dose SRCIOD
Planned Imaging Agent Administration SRCIOD
Performed Imaging Agent Administration SRCIOD
Rendition Selection DocumentCIOD
Enhanced X-Ray Radiation Dose SRCIOD
Enhanced MR ImageCIOD
MR SpectroscopyCIOD
Enhanced MR Color ImageCIOD
Raw DataCIOD
Enhanced CT ImageCIOD
Spatial RegistrationCIOD
Deformable Spatial RegistrationCIOD
Spatial FiducialsCIOD
Ophthalmic Photography 8 Bit ImageCIOD
Ophthalmic Photography 16 Bit ImageCIOD
Stereometric RelationshipCIOD
Hanging ProtocolCIOD
Encapsulated PDFCIOD
Encapsulated CDACIOD
Real World Value MappingCIOD
Enhanced XA ImageCIOD
Enhanced XRF ImageCIOD
RT Ion PlanCIOD
RT Ion Beams Treatment RecordCIOD
SegmentationCIOD
Ophthalmic Tomography ImageCIOD
X-Ray 3D Angiographic ImageCIOD
X-Ray 3D Craniofacial ImageCIOD
Breast Tomosynthesis ImageCIOD
Enhanced PET ImageCIOD
Surface SegmentationCIOD
Color PaletteCIOD
Enhanced US VolumeCIOD
Lensometry MeasurementsCIOD
Autorefraction MeasurementsCIOD
Keratometry MeasurementsCIOD
Subjective Refraction MeasurementsCIOD
Visual Acuity MeasurementsCIOD
Ophthalmic Axial MeasurementsCIOD
Intraocular Lens CalculationsCIOD
Generic Implant TemplateCIOD
Implant Assembly TemplateCIOD
Implant Template GroupCIOD
RT Beams Delivery InstructionCIOD
Ophthalmic Visual Field Static Perimetry MeasurementsCIOD
Intravascular Optical Coherence Tomography ImageCIOD
Ophthalmic Thickness MapCIOD
Surface Scan MeshCIOD
Surface Scan Point CloudCIOD
Legacy Converted Enhanced CT ImageCIOD
Legacy Converted Enhanced MR ImageCIOD
Legacy Converted Enhanced PET ImageCIOD
Corneal Topography MapCIOD
Breast Projection X-Ray ImageCIOD
Parametric MapCIOD
Wide Field Ophthalmic Photography Stereographic Projection ImageCIOD
Wide Field Ophthalmic Photography 3D Coordinates ImageCIOD
Tractography ResultsCIOD
RT Brachy Application Setup Delivery InstructionCIOD
Planar MPR Volumetric Presentation StateCIOD
Volume Rendering Volumetric Presentation StateCIOD
Content Assessment ResultsCIOD
CT Performed Procedure ProtocolCIOD
CT Defined Procedure ProtocolCIOD
Protocol ApprovalCIOD
XA Performed Procedure ProtocolCIOD
XA Defined Procedure ProtocolCIOD
Ophthalmic Optical Coherence Tomography En Face ImageCIOD
Ophthalmic Optical Coherence Tomography B-scan Volume AnalysisCIOD
Encapsulated STLCIOD
Encapsulated OBJCIOD
Encapsulated MTLCIOD
RT Physician IntentCIOD
RT Segment AnnotationCIOD
RT Radiation SetCIOD
C-Arm Photon-Electron RadiationCIOD
Tomotherapeutic RadiationCIOD
Robotic-Arm RadiationCIOD
RT Radiation Record SetCIOD
RT Radiation Salvage RecordCIOD
PatientMModule - Patient
Clinical Trial SubjectUModule - Patient
General StudyMModule - Study
Patient StudyUModule - Study
Clinical Trial StudyUModule - Study
General SeriesMModule - Series
Clinical Trial SeriesUModule - Series
Enhanced RT SeriesMModule - Series
General EquipmentMModule - Equipment
Enhanced General EquipmentMModule - Equipment
Frame of ReferenceUModule - Frame of Reference
General ReferenceMModule - RT Delivered Radiation
RT Delivery Device CommonMModule - RT Delivered Radiation
RT Radiation Record CommonMModule - RT Delivered Radiation
(0008,1156) Definition Source Sequence3Sequence
(0054,0410) Patient Orientation Code Sequence1Sequence
(0070,0081) Content Description2Long String
(0070,0084) Content Creator's Name3Person Name
(0070,0086) Content Creator's Identification Code Sequence3Sequence
(300A,0629) RT Tolerance Set Sequence3Sequence
(300A,062A) RT Tolerance Set Label1Long String
(300A,062B) Attribute Tolerance Values Sequence2Sequence
(0072,0026) Selector Attribute1CAttribute Tag
(0072,0028) Selector Value Number1CUnsigned Short
(0072,0052) Selector Sequence Pointer1CAttribute Tag
(0072,0054) Selector Sequence Pointer Private Creator1CLong String
(0072,0056) Selector Attribute Private Creator1CLong String
(0074,1057) Selector Sequence Pointer Items1CInteger String
(300A,062C) Tolerance Value1Double
(300A,065C) Patient Support Position Specification Method1Code String
(300A,0660) Patient Support Position Device Tolerance Sequence1CSequence
(300A,0631) Referenced RT Instance Sequence1CSequence
(300A,0635) Treatment Machine Special Mode Code Sequence1CSequence
(300A,0638) RT Radiation Physical and Geometric Content Detail Flag1Code String
(300A,0639) RT Record Flag1Code String
(300A,063F) Treatment Position Sequence1CSequence
(300A,0700) Treatment Session UID1Unique Identifier
(300A,0701) RT Radiation Usage1Code String
(300A,0708) Treatment Delivery Continuation Flag1Code String
(300A,0709) Treatment Record Content Origin1Code String
(300A,0714) RT Treatment Termination Status1Code String
(300A,0715) RT Treatment Termination Reason Code Sequence2CSequence
(300A,0716) Machine-Specific Treatment Termination Code Sequence3Sequence
(300A,0730) Treatment Termination Description2CShort Text
(300A,0731) Treatment Tolerance Violation Sequence2Sequence
(300A,073F) Confirmation Sequence2Sequence
(300A,0740) Interlock Sequence2Sequence
(300A,0780) Additional Parameter Recording Instance Sequence3Sequence
(3010,0030) Patient Equipment Relationship Code Sequence1Sequence
(3010,0034) User Content Long Label1Long String
(3010,0080) RT Treatment Technique Code Sequence1CSequence
RT Radiation Salvage RecordMModule - RT Delivered Radiation
SOP CommonMModule - RT Delivered Radiation
Common Instance ReferenceMModule - RT Delivered Radiation
Radiotherapy Common InstanceMModule - RT Delivered Radiation
C-Arm Photon-Electron Radiation RecordCIOD
Tomotherapeutic Radiation RecordCIOD
Robotic-Arm Radiation RecordCIOD
RT Radiation Set Delivery InstructionCIOD
RT Treatment PreparationCIOD
Enhanced RT ImageCIOD
Enhanced Continuous RT ImageCIOD
RT Patient Position Acquisition InstructionCIOD
Microscopy Bulk Simple AnnotationsCIOD
InventoryCIOD
Photoacoustic ImageCIOD
Confocal Microscopy ImageCIOD
Confocal Microscopy Tiled Pyramidal ImageCIOD
Basic DirectoryCIOD

Built with by Innolitics, a team of medical imaging software developers.

Data synced with official DICOM standard on 18 April 2024. The DICOM Standard is under continuous maintenance, and the current official version is available at http://www.dicomstandard.org/current/. DICOM Parts 3, 4, and 6, © NEMA. Please note that the most recent PDF version of the standard is the official reference, and should checked when making technical decisions.

Attribute Tolerance Values Sequence Attribute

Tag(300A,062B)
TypeRequired, Empty if Unknown (2)
KeywordAttributeToleranceValuesSequence
Value Multiplicity1
Value RepresentationSequence (SQ)

Tolerance values representing the allowed difference between the planned and actual values.

The Selector Attribute Macro identifies the Attributes for which the tolerances are specified.

Required if a tolerance value is specified for at least one Attribute which can be referenced by the Selector Attribute Macro.

See Section C.36.2.2.17.1.1.

Zero or more Items shall be included in this Sequence.

Selector Attribute Macro

10.17 Selector Attribute Macro

Table 10-20 specifies the Attributes of the Selector Attribute Macro, which identify either a particular value of an Attribute, all values of an Attribute, a specific Item in a Sequence, or all Items in a Sequence. The Attribute or Item may be nested within one or more Sequences, and/or a Private Attribute.

The invocation of the Selector Attribute Macro may define additional semantics. E.g., if the Selector Attribute Macro is used to select "all" values of an Attribute and then test that set of value against some condition, then an invocation might define whether it is required that at least one value in the set meet the condition or whether all values in the set must meet the condition.

Table 10-20a extends the Selector Attribute Macro with additional Attribute descriptors.

Table 10-20. Selector Attribute Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Selector Attribute

(0072,0026)

1C

Data Element Tag of the Attribute to be referenced.

Required if the selected content is not a Sequence Item.

Selector Value Number

(0072,0028)

1C

Non-negative integer identifying which value of a multi-valued Attribute identified by Selector Attribute (0072,0026) is to be referenced. The value 1 identifies the first value. The value 0 identifies all values.

When the Value Multiplicity of the Selector Attribute (0072,0026) is 1 then the value of this Attribute shall be 1.

Required if the selected content is a single Attribute of any VR other than SQ.

Selector Sequence Pointer

(0072,0052)

1C

Contains the Data Element Tags of the path to the Sequence that contains the Attribute that is identified by Selector Attribute (0072,0026) or to the Item(s) to be selected in Selector Sequence Pointer Items (0074,1057).

This Attribute shall have the same number of values as the level of nesting of Selector Attribute (0072,0026) or the selected Item(s).

Required if Selector Attribute (0072,0026) is nested in one or more Sequences or is absent.

See Section 10.17.1.1.

Selector Sequence Pointer Private Creator

(0072,0054)

1C

Identification of the creator of a group of Private Data Elements used to encode Attributes in the Selector Sequence Pointer (0072,0052).

This Attribute shall have the same number of values as Selector Sequence Pointer (0072,0052).

For values of the Selector Sequence Pointer (0072,0052) that are not the Data Element Tag of a Private Attribute, the corresponding value in Selector Sequence Pointer Private Creator (0072,0054) shall be empty.

Required if Selector Sequence Pointer (0072,0052) is present and one or more of the values of Selector Sequence Pointer (0072,0052) is the Data Element Tag of a Private Attribute.

See Section 10.17.1.2.

Selector Sequence Pointer Items

(0074,1057)

1C

Identification of the Item indices in the Selector Sequence Pointer (0072,0052).

This Attribute shall have the same number of values as the Selector Sequence Pointer (0072,0052).

The value 1 identifies the first Item of the corresponding Sequence. The value 0 identifies all Items of the corresponding Sequence.

Required if Selector Sequence Pointer (0072,0052) is present.

See Section 10.17.1.1.

Selector Attribute Private Creator

(0072,0056)

1C

Identification of the creator of a group of Private Data Elements.

Required if the Selector Attribute (0072,0026) value is the Data Element Tag of a Private Attribute.

See Section 10.17.1.2.


Table 10-20a. Extended Selector Attribute Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Selector Attribute Name

(0082,0018)

1

Name of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the Name column of Table 6-1 in PS3.6.

Selector Attribute Keyword

(0082,0019)

3

Keyword of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the Keyword column of Table 6-1 in PS3.6.

Selector Attribute VR

(0072,0050)

1

Value Representation of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the VR column of Table 6-1 in PS3.6.

Include Table 10-20 “Selector Attribute Macro Attributes”


10.17.1 Selector Attribute Macro Attribute Descriptions

10.17.1.1 Referencing Nested Elements

Examples of use are shown in Table 10-21.

The examples include the selection of a top level Attribute, a nested Attribute, one Item in a top level Sequence, all Items in a nested Sequence or a specific Item in all Items of a parent Sequence.

Table 10-21. Selector Attribute Macro Example

Example

Selector Attribute (0072,0026)

Selector Value Number (0072,0028)

Selector Sequence Pointer (0072,0052)

Selector Sequence Pointer Items (0074,1057)

Patient's Name (0010,0010)

(0010,0010)

1

absent

absent

Second value (e.g., PRIMARY or SECONDARY) in Image Type (0008,0008)

(0008,0008)

2

absent

absent

RT Beam Limiting Device Type (300A,00B8) for the second jaw in Beam Limiting Device Sequence (300A,00B6) specified for the first Beam in the Beam Sequence (300A,00B0) of an RT Plan

(300A,00B8)

1

(300A,00B0)\(300A,00B6)

1\2

Code Value (0008,0100) for the first Item in View Code Sequence (0054,0220)

(0008,0100)

1

(0054,0220)

1

The second Item in the Patient Setup Sequence (300A,0180) in the top level Data Set

absent

absent

(300A,0180)

2

The second Item in the Beam Limiting Device Sequence (300A,00B6) in third Item in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

3\2

All Items in the Beam Limiting Device Sequence (300A,00B6) in third Item in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

3\0

The second Item in the Beam Limiting Device Sequence (300A,00B6) in all Items in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

0\2


10.17.1.2 Private Attribute References

The Selector Sequence Pointer Private Creator (0072,0054) and the Selector Attribute Private Creator (0072,0056) each have a value that corresponds to the Private Creator Data Element numbers (gggg,00pp), where gggg is odd and pp ranges from 10 to FF. These identify a block of Private Data Elements within the block (gggg,ppxx). When Selector Attribute (0072,0026) or Selector Sequence Pointer (0072,0052) points to a Private Data Element (gggg,ppxx), it shall have the value (gggg,00xx).

Selector Attribute Macro

10.17 Selector Attribute Macro

Table 10-20 specifies the Attributes of the Selector Attribute Macro, which identify either a particular value of an Attribute, all values of an Attribute, a specific Item in a Sequence, or all Items in a Sequence. The Attribute or Item may be nested within one or more Sequences, and/or a Private Attribute.

The invocation of the Selector Attribute Macro may define additional semantics. E.g., if the Selector Attribute Macro is used to select "all" values of an Attribute and then test that set of value against some condition, then an invocation might define whether it is required that at least one value in the set meet the condition or whether all values in the set must meet the condition.

Table 10-20a extends the Selector Attribute Macro with additional Attribute descriptors.

Table 10-20. Selector Attribute Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Selector Attribute

(0072,0026)

1C

Data Element Tag of the Attribute to be referenced.

Required if the selected content is not a Sequence Item.

Selector Value Number

(0072,0028)

1C

Non-negative integer identifying which value of a multi-valued Attribute identified by Selector Attribute (0072,0026) is to be referenced. The value 1 identifies the first value. The value 0 identifies all values.

When the Value Multiplicity of the Selector Attribute (0072,0026) is 1 then the value of this Attribute shall be 1.

Required if the selected content is a single Attribute of any VR other than SQ.

Selector Sequence Pointer

(0072,0052)

1C

Contains the Data Element Tags of the path to the Sequence that contains the Attribute that is identified by Selector Attribute (0072,0026) or to the Item(s) to be selected in Selector Sequence Pointer Items (0074,1057).

This Attribute shall have the same number of values as the level of nesting of Selector Attribute (0072,0026) or the selected Item(s).

Required if Selector Attribute (0072,0026) is nested in one or more Sequences or is absent.

See Section 10.17.1.1.

Selector Sequence Pointer Private Creator

(0072,0054)

1C

Identification of the creator of a group of Private Data Elements used to encode Attributes in the Selector Sequence Pointer (0072,0052).

This Attribute shall have the same number of values as Selector Sequence Pointer (0072,0052).

For values of the Selector Sequence Pointer (0072,0052) that are not the Data Element Tag of a Private Attribute, the corresponding value in Selector Sequence Pointer Private Creator (0072,0054) shall be empty.

Required if Selector Sequence Pointer (0072,0052) is present and one or more of the values of Selector Sequence Pointer (0072,0052) is the Data Element Tag of a Private Attribute.

See Section 10.17.1.2.

Selector Sequence Pointer Items

(0074,1057)

1C

Identification of the Item indices in the Selector Sequence Pointer (0072,0052).

This Attribute shall have the same number of values as the Selector Sequence Pointer (0072,0052).

The value 1 identifies the first Item of the corresponding Sequence. The value 0 identifies all Items of the corresponding Sequence.

Required if Selector Sequence Pointer (0072,0052) is present.

See Section 10.17.1.1.

Selector Attribute Private Creator

(0072,0056)

1C

Identification of the creator of a group of Private Data Elements.

Required if the Selector Attribute (0072,0026) value is the Data Element Tag of a Private Attribute.

See Section 10.17.1.2.


Table 10-20a. Extended Selector Attribute Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Selector Attribute Name

(0082,0018)

1

Name of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the Name column of Table 6-1 in PS3.6.

Selector Attribute Keyword

(0082,0019)

3

Keyword of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the Keyword column of Table 6-1 in PS3.6.

Selector Attribute VR

(0072,0050)

1

Value Representation of the Selector Attribute (0072,0026).

For Standard Data Elements, this shall be the value in the VR column of Table 6-1 in PS3.6.

Include Table 10-20 “Selector Attribute Macro Attributes”


10.17.1 Selector Attribute Macro Attribute Descriptions

10.17.1.1 Referencing Nested Elements

Examples of use are shown in Table 10-21.

The examples include the selection of a top level Attribute, a nested Attribute, one Item in a top level Sequence, all Items in a nested Sequence or a specific Item in all Items of a parent Sequence.

Table 10-21. Selector Attribute Macro Example

Example

Selector Attribute (0072,0026)

Selector Value Number (0072,0028)

Selector Sequence Pointer (0072,0052)

Selector Sequence Pointer Items (0074,1057)

Patient's Name (0010,0010)

(0010,0010)

1

absent

absent

Second value (e.g., PRIMARY or SECONDARY) in Image Type (0008,0008)

(0008,0008)

2

absent

absent

RT Beam Limiting Device Type (300A,00B8) for the second jaw in Beam Limiting Device Sequence (300A,00B6) specified for the first Beam in the Beam Sequence (300A,00B0) of an RT Plan

(300A,00B8)

1

(300A,00B0)\(300A,00B6)

1\2

Code Value (0008,0100) for the first Item in View Code Sequence (0054,0220)

(0008,0100)

1

(0054,0220)

1

The second Item in the Patient Setup Sequence (300A,0180) in the top level Data Set

absent

absent

(300A,0180)

2

The second Item in the Beam Limiting Device Sequence (300A,00B6) in third Item in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

3\2

All Items in the Beam Limiting Device Sequence (300A,00B6) in third Item in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

3\0

The second Item in the Beam Limiting Device Sequence (300A,00B6) in all Items in the Beam Sequence (300A,00B0) of an RT Plan

absent

absent

(300A,00B0)\(300A,00B6)

0\2


10.17.1.2 Private Attribute References

The Selector Sequence Pointer Private Creator (0072,0054) and the Selector Attribute Private Creator (0072,0056) each have a value that corresponds to the Private Creator Data Element numbers (gggg,00pp), where gggg is odd and pp ranges from 10 to FF. These identify a block of Private Data Elements within the block (gggg,ppxx). When Selector Attribute (0072,0026) or Selector Sequence Pointer (0072,0052) points to a Private Data Element (gggg,ppxx), it shall have the value (gggg,00xx).

Section C.36.2.2.17.1.1

C.36.2.2.17.1.1 Attribute Tolerance Values Sequence

The Attribute Tolerance Values Sequence (300A,062B) allows for the reference to any numerical parameter in an RT Radiation IOD. The RT Tolerance Set Macro is invoked to specify a tolerance value for this parameter. The reference specification is conveyed by the Selector Attribute Macro, which allows reference to a tag on any level of nested Sequences, and to refer to specific Items in the Sequence. The unit of the tolerance value is the unit as specified by the data element tag referenced in the Selector Attribute (0072,0026).