CR ImageCIOD
CT ImageCIOD
MR ImageCIOD
NM ImageCIOD
US ImageCIOD
US Multi-frame ImageCIOD
Secondary Capture ImageCIOD
Multi-frame Single Bit SC ImageCIOD
Multi-frame Grayscale Byte SC ImageCIOD
Multi-frame Grayscale Word SC ImageCIOD
Multi-frame True Color SC ImageCIOD
X-Ray Angiographic ImageCIOD
X-Ray Radiofluoroscopic ImageCIOD
RT ImageCIOD
RT DoseCIOD
RT Structure SetCIOD
RT PlanCIOD
PatientMModule - Patient
Clinical Trial SubjectUModule - Patient
General StudyMModule - Study
Patient StudyUModule - Study
Clinical Trial StudyUModule - Study
RT SeriesMModule - Series
Clinical Trial SeriesUModule - Series
Frame of ReferenceUModule - Frame of Reference
General EquipmentMModule - Equipment
RT General PlanMModule - Plan
RT PrescriptionUModule - Plan
RT Tolerance TablesUModule - Plan
RT Patient SetupUModule - Plan
RT Fraction SchemeUModule - Plan
RT BeamsCModule - Plan
RT Brachy Application SetupsCModule - Plan
(300A,0200) Brachy Treatment Technique1Code String
(300A,0202) Brachy Treatment Type1Code String
(300A,0206) Treatment Machine Sequence1Sequence
(300A,0210) Source Sequence1Sequence
(300A,0230) Application Setup Sequence1Sequence
(300A,0232) Application Setup Type1Code String
(300A,0234) Application Setup Number1Integer String
(300A,0236) Application Setup Name3Long String
(300A,0238) Application Setup Manufacturer3Long String
(300A,0240) Template Number3Integer String
(300A,0242) Template Type3Short String
(300A,0244) Template Name3Long String
(300A,0250) Total Reference Air Kerma1Decimal String
(300A,0260) Brachy Accessory Device Sequence3Sequence
(300A,0280) Channel Sequence1Sequence
(3006,0084) Referenced ROI Number2CInteger String
(300A,00E1) Material ID3Short String
(300A,0110) Number of Control Points1Integer String
(300A,0271) Channel Effective Length3Decimal String
(300A,0272) Channel Inner Length2CDecimal String
(300A,0273) Afterloader Channel ID3Short String
(300A,0274) Source Applicator Tip Length2CDecimal String
(300A,0282) Channel Number1Integer String
(300A,0284) Channel Length2Decimal String
(300A,0286) Channel Total Time1Decimal String
(300A,0288) Source Movement Type1Code String
(300A,028A) Number of Pulses1CInteger String
(300A,028C) Pulse Repetition Interval1CDecimal String
(300A,0290) Source Applicator Number3Integer String
(300A,0291) Source Applicator ID2CShort String
(300A,0292) Source Applicator Type1CCode String
(300A,0294) Source Applicator Name3Long String
(300A,0296) Source Applicator Length1CDecimal String
(300A,0298) Source Applicator Manufacturer3Long String
(300A,029C) Source Applicator Wall Nominal Thickness3Decimal String
(300A,029E) Source Applicator Wall Nominal Transmission3Decimal String
(300A,02A0) Source Applicator Step Size1CDecimal String
(300A,02A2) Transfer Tube Number2Integer String
(300A,02A4) Transfer Tube Length2CDecimal String
(300A,02B0) Channel Shield Sequence3Sequence
(300A,02C8) Final Cumulative Time Weight1CDecimal String
(300A,02D0) Brachy Control Point Sequence1Sequence
(300C,000E) Referenced Source Number1Integer String
(300C,0042) Referenced Reference Image Sequence3Sequence
ApprovalUModule - Plan
General ReferenceUModule - Plan
SOP CommonMModule - Plan
Common Instance ReferenceUModule - Plan
PET ImageCIOD
Digital X-Ray ImageCIOD
Digital Mammography X-Ray ImageCIOD
Digital Intra-Oral X-Ray ImageCIOD
RT Beams Treatment RecordCIOD
RT Brachy Treatment RecordCIOD
RT Treatment Summary RecordCIOD
VL Endoscopic ImageCIOD
VL Microscopic ImageCIOD
VL Slide-Coordinates Microscopic ImageCIOD
VL Photographic ImageCIOD
Video Endoscopic ImageCIOD
Video Microscopic ImageCIOD
Video Photographic ImageCIOD
VL Whole Slide Microscopy ImageCIOD
Real-Time Video Endoscopic ImageCIOD
Real-Time Video Photographic ImageCIOD
Grayscale Softcopy Presentation StateCIOD
Color Softcopy Presentation StateCIOD
Pseudo-Color Softcopy Presentation StateCIOD
Blending Softcopy Presentation StateCIOD
Basic Structured DisplayCIOD
XA/XRF Grayscale Softcopy Presentation StateCIOD
Advanced Blending Presentation StateCIOD
Basic Voice Audio WaveformCIOD
12-Lead ECGCIOD
General ECGCIOD
Ambulatory ECGCIOD
Hemodynamic WaveformCIOD
Basic Cardiac Electrophysiology WaveformCIOD
Arterial Pulse WaveformCIOD
Respiratory WaveformCIOD
General Audio WaveformCIOD
Real-Time Audio WaveformCIOD
Basic Text SRCIOD
Enhanced SRCIOD
Comprehensive SRCIOD
Key Object Selection DocumentCIOD
Mammography CAD SRCIOD
Chest CAD SRCIOD
Procedure LogCIOD
X-Ray Radiation Dose SRCIOD
Spectacle Prescription ReportCIOD
Colon CAD SRCIOD
Macular Grid Thickness and Volume ReportCIOD
Implantation Plan SR DocumentCIOD
Comprehensive 3D SRCIOD
Radiopharmaceutical Radiation Dose SRCIOD
Extensible SRCIOD
Acquisition Context SRCIOD
Simplified Adult Echo SRCIOD
Patient Radiation Dose Structured ReportCIOD
Planned Imaging Agent Administration SRCIOD
Performed Imaging Agent Administration SRCIOD
Rendition Selection DocumentCIOD
Enhanced MR ImageCIOD
MR SpectroscopyCIOD
Enhanced MR Color ImageCIOD
Raw DataCIOD
Enhanced CT ImageCIOD
Spatial RegistrationCIOD
Deformable Spatial RegistrationCIOD
Spatial FiducialsCIOD
Ophthalmic Photography 8 Bit ImageCIOD
Ophthalmic Photography 16 Bit ImageCIOD
Stereometric RelationshipCIOD
Hanging ProtocolCIOD
Encapsulated PDFCIOD
Encapsulated CDACIOD
Real World Value MappingCIOD
Enhanced XA ImageCIOD
Enhanced XRF ImageCIOD
RT Ion PlanCIOD
RT Ion Beams Treatment RecordCIOD
SegmentationCIOD
Ophthalmic Tomography ImageCIOD
X-Ray 3D Angiographic ImageCIOD
X-Ray 3D Craniofacial ImageCIOD
Breast Tomosynthesis ImageCIOD
Enhanced PET ImageCIOD
Surface SegmentationCIOD
Color PaletteCIOD
Enhanced US VolumeCIOD
Lensometry MeasurementsCIOD
Autorefraction MeasurementsCIOD
Keratometry MeasurementsCIOD
Subjective Refraction MeasurementsCIOD
Visual Acuity MeasurementsCIOD
Ophthalmic Axial MeasurementsCIOD
Intraocular Lens CalculationsCIOD
Generic Implant TemplateCIOD
Implant Assembly TemplateCIOD
Implant Template GroupCIOD
RT Beams Delivery InstructionCIOD
Ophthalmic Visual Field Static Perimetry MeasurementsCIOD
Intravascular Optical Coherence Tomography ImageCIOD
Ophthalmic Thickness MapCIOD
Surface Scan MeshCIOD
Surface Scan Point CloudCIOD
Legacy Converted Enhanced CT ImageCIOD
Legacy Converted Enhanced MR ImageCIOD
Legacy Converted Enhanced PET ImageCIOD
Corneal Topography MapCIOD
Breast Projection X-Ray ImageCIOD
Parametric MapCIOD
Wide Field Ophthalmic Photography Stereographic Projection ImageCIOD
Wide Field Ophthalmic Photography 3D Coordinates ImageCIOD
Tractography ResultsCIOD
RT Brachy Application Setup Delivery InstructionCIOD
Planar MPR Volumetric Presentation StateCIOD
Volume Rendering Volumetric Presentation StateCIOD
Content Assessment ResultsCIOD
CT Performed Procedure ProtocolCIOD
CT Defined Procedure ProtocolCIOD
Protocol ApprovalCIOD
Ophthalmic Optical Coherence Tomography En Face ImageCIOD
Ophthalmic Optical Coherence Tomography B-scan Volume AnalysisCIOD
Encapsulated STLCIOD
Encapsulated OBJCIOD
Encapsulated MTLCIOD
RT Physician IntentCIOD
RT Segment AnnotationCIOD
RT Radiation SetCIOD
C-Arm Photon-Electron RadiationCIOD
Tomotherapeutic RadiationCIOD
Robotic-Arm RadiationCIOD
Basic DirectoryCIOD

Built with by Innolitics, a team of medical imaging software developers.

Data synced with official DICOM standard on 12 May 2020. The DICOM Standard is under continuous maintenance, and the current official version is available at http://www.dicomstandard.org/current/. DICOM Parts 3, 4, and 6, © NEMA. Please note that the most recent PDF version of the standard is the official reference, and should checked when making technical decisions.

Pulse Repetition Interval Attribute

Tag(300A,028C)
TypeConditionally Required (1C)
KeywordPulseRepetitionInterval
Value Multiplicity1
Value RepresentationDecimal String (DS)

Pulse repetition interval (sec) for current Channel. Required if Brachy Treatment Type (300A,0202) is PDR.