Computed Radiography ImageCIOD
CT ImageCIOD
MR ImageCIOD
Nuclear Medicine ImageCIOD
Ultrasound ImageCIOD
Ultrasound Multi-frame ImageCIOD
Secondary Capture ImageCIOD
Multi-frame Single Bit Secondary Capture ImageCIOD
Multi-frame Grayscale Byte Secondary Capture ImageCIOD
Multi-frame Grayscale Word Secondary Capture ImageCIOD
Multi-frame True Color Secondary Capture ImageCIOD
X-Ray Angiographic ImageCIOD
X-Ray Radiofluoroscopic ImageCIOD
RT ImageCIOD
RT DoseCIOD
RT Structure SetCIOD
RT PlanCIOD
Positron Emission Tomography ImageCIOD
Digital X-Ray ImageCIOD
Digital Mammography X-Ray ImageCIOD
Digital Intra-Oral X-Ray ImageCIOD
RT Beams Treatment RecordCIOD
RT Brachy Treatment RecordCIOD
RT Treatment Summary RecordCIOD
VL Endoscopic ImageCIOD
VL Microscopic ImageCIOD
VL Slide-Coordinates Microscopic ImageCIOD
VL Photographic ImageCIOD
Video Endoscopic ImageCIOD
Video Microscopic ImageCIOD
Video Photographic ImageCIOD
VL Whole Slide Microscopy ImageCIOD
Real-Time Video Endoscopic ImageCIOD
Real-Time Video Photographic ImageCIOD
Dermoscopic Photography ImageCIOD
Grayscale Softcopy Presentation StateCIOD
Color Softcopy Presentation StateCIOD
Pseudo-Color Softcopy Presentation StateCIOD
Blending Softcopy Presentation StateCIOD
Basic Structured DisplayCIOD
XA/XRF Grayscale Softcopy Presentation StateCIOD
Advanced Blending Presentation StateCIOD
Variable Modality LUT Softcopy Presentation StateCIOD
Basic Voice Audio WaveformCIOD
12-Lead ECGCIOD
General ECGCIOD
Ambulatory ECGCIOD
Hemodynamic WaveformCIOD
Basic Cardiac Electrophysiology WaveformCIOD
Arterial Pulse WaveformCIOD
Respiratory WaveformCIOD
General Audio WaveformCIOD
Real-Time Audio WaveformCIOD
Routine Scalp ElectroencephalogramCIOD
ElectromyogramCIOD
ElectrooculogramCIOD
Sleep ElectroencephalogramCIOD
Multi-channel Respiratory WaveformCIOD
Body Position WaveformCIOD
General 32-bit ECGCIOD
Basic Text SRCIOD
Enhanced SRCIOD
Comprehensive SRCIOD
Key Object Selection DocumentCIOD
Mammography CAD SRCIOD
Chest CAD SRCIOD
Procedure LogCIOD
X-Ray Radiation Dose SRCIOD
Spectacle Prescription ReportCIOD
Colon CAD SRCIOD
Macular Grid Thickness and Volume ReportCIOD
Implantation Plan SR DocumentCIOD
Comprehensive 3D SRCIOD
Radiopharmaceutical Radiation Dose SRCIOD
Extensible SRCIOD
Acquisition Context SRCIOD
Simplified Adult Echo SRCIOD
Patient Radiation Dose SRCIOD
Planned Imaging Agent Administration SRCIOD
Performed Imaging Agent Administration SRCIOD
Rendition Selection DocumentCIOD
Enhanced X-Ray Radiation Dose SRCIOD
Enhanced MR ImageCIOD
MR SpectroscopyCIOD
Enhanced MR Color ImageCIOD
Raw DataCIOD
Enhanced CT ImageCIOD
Spatial RegistrationCIOD
Deformable Spatial RegistrationCIOD
Spatial FiducialsCIOD
Ophthalmic Photography 8 Bit ImageCIOD
Ophthalmic Photography 16 Bit ImageCIOD
Stereometric RelationshipCIOD
Hanging ProtocolCIOD
Encapsulated PDFCIOD
Encapsulated CDACIOD
Real World Value MappingCIOD
Enhanced XA ImageCIOD
Enhanced XRF ImageCIOD
RT Ion PlanCIOD
RT Ion Beams Treatment RecordCIOD
SegmentationCIOD
Ophthalmic Tomography ImageCIOD
X-Ray 3D Angiographic ImageCIOD
X-Ray 3D Craniofacial ImageCIOD
Breast Tomosynthesis ImageCIOD
Enhanced PET ImageCIOD
Surface SegmentationCIOD
Color PaletteCIOD
Enhanced US VolumeCIOD
Lensometry MeasurementsCIOD
Autorefraction MeasurementsCIOD
Keratometry MeasurementsCIOD
Subjective Refraction MeasurementsCIOD
Visual Acuity MeasurementsCIOD
Ophthalmic Axial MeasurementsCIOD
Intraocular Lens CalculationsCIOD
Generic Implant TemplateCIOD
Implant Assembly TemplateCIOD
Implant Template GroupCIOD
RT Beams Delivery InstructionCIOD
Ophthalmic Visual Field Static Perimetry MeasurementsCIOD
Intravascular Optical Coherence Tomography ImageCIOD
Ophthalmic Thickness MapCIOD
Surface Scan MeshCIOD
Surface Scan Point CloudCIOD
Legacy Converted Enhanced CT ImageCIOD
Legacy Converted Enhanced MR ImageCIOD
Legacy Converted Enhanced PET ImageCIOD
Corneal Topography MapCIOD
Breast Projection X-Ray ImageCIOD
PatientMModule - Patient
Clinical Trial SubjectUModule - Patient
General StudyMModule - Study
Patient StudyUModule - Study
Clinical Trial StudyUModule - Study
General SeriesMModule - Series
Clinical Trial SeriesUModule - Series
DX SeriesMModule - Series
Enhanced Mammography SeriesMModule - Series
Frame of ReferenceMModule - Frame of Reference
SynchronizationCModule - Frame of Reference
General EquipmentMModule - Equipment
Enhanced General EquipmentMModule - Equipment
Enhanced Mammography ImageMModule - Image
Breast ViewMModule - Image
Image PixelMModule - Image
Enhanced Contrast/BolusCModule - Image
DeviceUModule - Image
InterventionUModule - Image
Acquisition ContextMModule - Image
Multi-frame Functional GroupsMModule - Image
(0008,0023) Content Date1Date
(0008,0033) Content Time1Time
(0020,0013) Instance Number1Integer String
(0020,0242) SOP Instance UID of Concatenation Source1CUnique Identifier
(0020,9161) Concatenation UID1CUnique Identifier
(0020,9162) In-concatenation Number1CUnsigned Short
(0020,9163) In-concatenation Total Number3Unsigned Short
(0020,9228) Concatenation Frame Offset Number1CUnsigned Long
(0022,0028) Stereo Pairs Present3Code String
(0028,0008) Number of Frames1Integer String
(0028,6010) Representative Frame Number3Unsigned Short
(5200,9229) Shared Functional Groups Sequence1Sequence
(0008,1140) Referenced Image Sequence2Sequence
(0008,9124) Derivation Image Sequence2Sequence
(0018,1006) Grid ID3Long String
(0018,7040) Grid Absorbing Material3Long Text
(0018,7041) Grid Spacing Material3Long Text
(0018,7042) Grid Thickness3Decimal String
(0018,7044) Grid Pitch3Decimal String
(0018,7046) Grid Aspect Ratio3Integer String
(0018,7048) Grid Period3Decimal String
(0018,704C) Grid Focal Distance3Decimal String
(0018,9341) Contrast/Bolus Usage Sequence1Sequence
(0018,9405) Positioner Position Sequence1Sequence
(0018,9407) Collimator Shape Sequence1Sequence
(0018,1700) Collimator Shape1Code String
(0018,1702) Collimator Left Vertical Edge1CInteger String
(0018,1704) Collimator Right Vertical Edge1CInteger String
(0018,1706) Collimator Upper Horizontal Edge1CInteger String
(0018,1708) Collimator Lower Horizontal Edge1CInteger String
(0018,1710) Center of Circular Collimator1CInteger String
(0018,1712) Radius of Circular Collimator1CInteger String
(0018,1720) Vertices of the Polygonal Collimator1CInteger String
(0018,9412) XA/XRF Frame Characteristics Sequence1Sequence
(0018,9417) Frame Acquisition Sequence1Sequence
(0018,9432) Field of View Sequence1Sequence
(0018,9451) Frame Detector Parameters Sequence1Sequence
(0018,9455) Calibration Sequence1Sequence
(0018,9462) Isocenter Reference System Sequence1Sequence
(0018,9472) Frame Display Shutter Sequence1Sequence
(0018,9476) X-Ray Geometry Sequence1Sequence
(0018,9477) Irradiation Event Identification Sequence1Sequence
(0018,9541) Detector Position Sequence1Sequence
(0018,9542) X-Ray Acquisition Dose Sequence1Sequence
(0018,9555) X-Ray Grid Sequence1Sequence
(0018,9556) X-Ray Filter Sequence1Sequence
(0020,9071) Frame Anatomy Sequence1Sequence
(0020,9111) Frame Content Sequence1Sequence
(0028,9132) Frame VOI LUT Sequence1Sequence
(0028,9145) Pixel Value Transformation Sequence1Sequence
(0028,9443) Frame Pixel Data Properties Sequence1Sequence
(5200,9230) Per-Frame Functional Groups Sequence1CSequence
(7FE0,0003) Encapsulated Pixel Data Value Total Length3UV
Multi-frame DimensionUModule - Image
Patient OrientationMModule - Image
SpecimenUModule - Image
SOP CommonMModule - Image
Common Instance ReferenceUModule - Image
Frame ExtractionCModule - Image
Parametric MapCIOD
Wide Field Ophthalmic Photography Stereographic Projection ImageCIOD
Wide Field Ophthalmic Photography 3D Coordinates ImageCIOD
Tractography ResultsCIOD
RT Brachy Application Setup Delivery InstructionCIOD
Planar MPR Volumetric Presentation StateCIOD
Volume Rendering Volumetric Presentation StateCIOD
Content Assessment ResultsCIOD
CT Performed Procedure ProtocolCIOD
CT Defined Procedure ProtocolCIOD
Protocol ApprovalCIOD
XA Performed Procedure ProtocolCIOD
XA Defined Procedure ProtocolCIOD
Ophthalmic Optical Coherence Tomography En Face ImageCIOD
Ophthalmic Optical Coherence Tomography B-scan Volume AnalysisCIOD
Encapsulated STLCIOD
Encapsulated OBJCIOD
Encapsulated MTLCIOD
RT Physician IntentCIOD
RT Segment AnnotationCIOD
RT Radiation SetCIOD
C-Arm Photon-Electron RadiationCIOD
Tomotherapeutic RadiationCIOD
Robotic-Arm RadiationCIOD
RT Radiation Record SetCIOD
RT Radiation Salvage RecordCIOD
C-Arm Photon-Electron Radiation RecordCIOD
Tomotherapeutic Radiation RecordCIOD
Robotic-Arm Radiation RecordCIOD
RT Radiation Set Delivery InstructionCIOD
RT Treatment PreparationCIOD
Enhanced RT ImageCIOD
Enhanced Continuous RT ImageCIOD
RT Patient Position Acquisition InstructionCIOD
Microscopy Bulk Simple AnnotationsCIOD
InventoryCIOD
Photoacoustic ImageCIOD
Confocal Microscopy ImageCIOD
Confocal Microscopy Tiled Pyramidal ImageCIOD
Basic DirectoryCIOD

Built with by Innolitics, a team of medical imaging software developers.

Data synced with official DICOM standard on 19 March 2024. The DICOM Standard is under continuous maintenance, and the current official version is available at http://www.dicomstandard.org/current/. DICOM Parts 3, 4, and 6, © NEMA. Please note that the most recent PDF version of the standard is the official reference, and should checked when making technical decisions.

Collimator Right Vertical Edge Attribute

Tag(0018,1704)
TypeConditionally Required (1C)
KeywordCollimatorRightVerticalEdge
Value Multiplicity1
Value RepresentationInteger String (IS)

Required if Collimator Shape (0018,1700) is RECTANGULAR. Location of the right edge of the rectangular collimator expressed as effective pixel column. See Section C.8.7.3.1.1 and Section C.8.19.6.12.1.

Note

Part of the X-Ray Collimator Functional Group Macro with usage: M

Section C.8.7.3.1.1

C.8.7.3.1.1 Collimator Vertical and Horizontal Edges

These Attributes specify the pixel row or column where the X-Ray beam is fully obscured by a rectangular collimator:

  • if the left edge of the collimator is not visible, Collimator Left Vertical Edge (0018,1702) shall have a value of 0;

  • if the right edge of the collimator is not visible, Collimator Right Vertical Edge (0018,1704) value shall be 1 greater than the value of Columns (0028,0011) Attribute;

  • if the top edge of the collimator is not visible, Collimator Upper Horizontal Edge (0018,1706) shall have a value of 0;

  • if the bottom edge of the collimator is not visible, Collimator Lower Horizontal Edge (0018,1708) value shall be 1 greater than the value of Rows (0028,0010) Attribute.

Section C.8.19.6.12.1

C.8.19.6.12.1 X-Ray Collimator Macro Attribute Descriptions

The top left pixel of the image has a pixel row and column value of 1.